Overview

Our Raychem OXSU Heat Shrinkable Outdoor Termination Kits have a specifically formulated electrical stress control compound that is based on extensive experience with Raychem ceramic semiconductor technology. The ZnO-based stress control system is integrated into heat-shrinkable insulating tubing. During heating, the tubing shrinks to the original smaller extruded diameter, fitting tightly over a wide range of cable sizes and profiles. This stress control system fills any irregularities, bonds to the insulation and provides high electrical performance. The heat shrink terminations are sold in kits and can be used with mechanical and compression lugs suitable for both copper and aluminum conductors.

These heat shrink termination kits are perfectly suited for both indoor (IXSU) and outdoor (OXSU) applications for 1-core or 3-core polymeric cables thus guaranteeing the maximum mechanical protection for cable connections.

grey bar

Key Features

  • Integrated stress control material, ZnO (Varistor)
  • Specification conformity: IEC 60502-4, CENELEC HD 629.1, IEEE-48
  • Indoor and outdoor application
  • Easily adaptable to specific customer needs
  • Decades-long shelf life, when stored under recommended conditions
grey bar
grey bar
FAQ

Frequently Asked Questions

Question: What comes supplied in TE's Raychem OXSU Heat Shrinkable Outdoor Termination Kits?

Answer: These kits come with an HVOT Termination tube, yellow stress grading mastic and red moisture sealing mastic. Lugs are generally not included in the standard kits to offer you the flexibility to choose between compression or mechanical lugs. The kit includes all materials to complete either 3 single-core or 1 three-core terminations, with the exception of the main conductor phase lug.

 

Question: What specification are the Heat Shrinkable Outdoor Termination Kits compliant with?

Answer: Our Heat Shrinkable Outdoor Termination Kits are fully compliant with the requirements of CENELEC HD.629.1 S2.

 

Question: Does TE offer installation training for the Heat Shrinkable Outdoor Termination Kits? 

Answer: Yes, our Heat Shrinkable Outdoor Termination Kits are part of our training program. We can offer different installation training options depending on your needs. This ranges from on-site product demonstrations to complete training courses at one of our global training facilities. Learn more at: TE.com/trainingcenter

Features

Please review product documents or contact us for the latest agency approval information.  

Industry Standards

  • Pollution Level (IEC 60815)  II, III, IV

  • Compatible With Approved Standards Products  IEC 60502-4, HD CENELEC 629.1, CENELEC HD 620 A2, CENELEC HD 629.1

Product Type Features

  • Shelf Life  Unlimited

  • Installation Technology  Heat Shrink

  • Cable Shield Style  Wire, Tape/Wire

  • Termination Length (mm) 500, 340, 300, 440, 560

  • Power Component Options  Mechanical Lug Included (M16, Conductor), Mechanical Lug Included (Shield), Mechanical Lug Included (M12, Conductor), Mechanical Connectors Included

Packaging Features

  • Packaging Quantity  1

Operation/Application

  • Power Component Application Type  Outdoor

Product Availability

  • Product Availability  Europe, Middle East & Africa, Asia, Germany, Americas, Australia, New Zealand & Pacific Islands, China, Worldwide

Other

  • Installation Instruction  Dutch, Danish, English, German, Flemish, Spanish, Norwegian, Swedish, Italian, French, Finnish

  • EU RoHS Compliance  Compliant, Compliant with Exemptions

  • EU ELV Compliance  Compliant with Exemptions, Compliant

Electrical Characteristics

  • Voltage Class (kV) 12/20(24), 20.8/36(42), 6.35/11(12), ≤ 24, 8.7/15(17.5), 19/33(36)

Configuration Features

  • Number of Cores  1, 3

Dimensions

  • Compatible Cable Cross-Section Range (mm²) 185 – 400, 300 – 400, 400 – 800, 25 – 95, 95 – 240, 500 – 800, 16 – 35, 500 – 630, 10 – 35, 35 – 70, 240 – 500, 120 – 400, 50 – 120, 120 – 300, 240 – 400, 25 – 70, 70 – 240, 70 – 185

  • Compatible Insulation Diameter Range (mm) 17.9 – 23.4, 27.4 – 37.8, 25.4 – 32, 32.4 – 42.8, 17.9 – 25, 35.1 – 46.9, 21.9 – 32.6, 32 – 32.6, 32.8 – 41.6, 27.7 – 35.6, 42.6 – 49.2, 34 – 42.2, 34.4 – 40, 13.7 – 16.3, 13.7 – 20.8, 18.6 – 28.4, 30.8 – 42.8, 25.7 – 36.2, 27.8 – 37.6

  • Compatible Insulation Diameter Range (in) .704 – .984, 1.667 – 1.937, 1 – 1.259, 1.291 – 1.637, 1.078 – 1.488, .539 – .641, 1.381 – 1.846, 1.212 – 1.685, 1.354 – 1.574, .539 – .818, .862 – 1.283, 1.338 – 1.661, .732 – 1.118, 1.094 – 1.48, 1.011 – 1.425, .704 – .921, 1.09 – 1.401, 1.275 – 1.685, 1.259 – 1.283

  • Shed Inside Diameter (mm) 140, 80, 95, 90, 120

  • Shed Inside Diameter (in) 4.724, 3.74, 3.149, 5.511, 3.543

  • Cable Termination Tail Length (mm) 1200, 450

  • Cable Termination Tail Length (in) 17.716, 47.244

Body Features

  • Insulation Material  Plastic, Plastic (XLPE)

  • Number of Sheds  1, 4, 3

Housing Features

  • Armoring Material  No

Reference Number

  • TE Internal Number CAT-OXSU